Lighting levels and visual symptoms among employees of a food company in Machachi, Ecuador

Authors

DOI:

https://doi.org/10.62574/bb6z7kx8

Keywords:

lighting, asthenopia, occupational health

Abstract

Objective: to assess workstation lighting levels and visual symptoms among employees of a small food company in Machachi, Ecuador. Method: observational, descriptive, cross-sectional study of all 23 workstations. Illuminance was measured on the work plane and the INSHT subjective lighting questionnaire was applied. Results: only 26.1% of workstations met the recommended level; the median was 138 lux, range 57.9-693 lux. Visual symptoms were reported by 73.9% of workers, mainly tired eyes and itching, 35% each. Twenty-six per cent needed more light and 22% reported glare or reflections. Conclusion: lighting is insufficient and uneven, and visual symptoms are frequent.

Downloads

Download data is not yet available.

References

Sheppard AL, Wolffsohn JS. Digital eye strain: prevalence, measurement and amelioration. BMJ Open Ophthalmol. 2018;3(1):e000146. doi:10.1136/bmjophth-2018-000146

Rosenfield M. Computer vision syndrome: a review of ocular causes and potential treatments. Ophthalmic Physiol Opt. 2011;31(5):502-15. doi:10.1111/j.1475-1313.2011.00834.x

Blehm C, Vishnu S, Khattak A, Mitra S, Yee RW. Computer vision syndrome: a review. Surv Ophthalmol. 2005;50(3):253-62. doi:10.1016/j.survophthal.2005.02.008

Ccami-Bernal F, Soriano-Moreno DR, Romero-Robles MA, Barriga-Chambi F, Tuco KG, Castro-Diaz SD, et al. Prevalence of computer vision syndrome: a systematic review and meta-analysis. J Optom. 2024;17(1):100482. doi:10.1016/j.optom.2023.100482

Gizachew N, Abegaz T, Demis T, Gashaw M, Demoze L. Assessment of computer vision syndrome and associated factors among employees of Ethio-telecom in Addis Ababa, Ethiopia. Front Public Health. 2025;13:1524173. doi:10.3389/fpubh.2025.1524173

Sánchez-Brau M, Domenech-Amigot B, Brocal-Fernández F, Quesada-Rico JA, Seguí-Crespo M. Prevalence of computer vision syndrome and its relationship with ergonomic and individual factors in presbyopic VDT workers using progressive addition lenses. Int J Environ Res Public Health. 2020;17(3):1003. doi:10.3390/ijerph17031003

Gasheya KA, Belay AA, Abegaze T, Zele YT, Daba C. Computer vision syndrome and ergonomic risk factors among workers of the Commercial Bank of Ethiopia in Addis Ababa, Ethiopia: an institutional-based cross-sectional study. Front Public Health. 2024;12:1341031. doi:10.3389/fpubh.2024.1341031

Silva-Peñaherrera M, Merino-Salazar P, Benavides FG, López-Ruiz M, Gómez-García AR. La salud ocupacional en Ecuador: una comparación con las encuestas sobre condiciones de trabajo en América Latina. Rev Bras Saúde Ocup. 2020;45:e20.

von Elm E, Altman DG, Egger M, Pocock SJ, Gøtzsche PC, Vandenbroucke JP. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. Lancet. 2007;370(9596):1453-7.

Fang Y, Liu C, Zhao C, Zhang H, Wang W, Zou N. A study of the effects of different indoor lighting environments on computer work fatigue. Int J Environ Res Public Health. 2022;19(11):6866. doi:10.3390/ijerph19116866

Ferreira F, Fonseca AC, Ferreira S, Pinto-Coelho L, Rodrigues MA. Beyond visual comfort: comparing pupillometry and subjective measures of cognitive strain in workplace lighting. Front Public Health. 2026;14:1875100. doi:10.3389/fpubh.2026.1875100

Arnao Bedregal A, Noriega Herrera KG, Benites-Zapata VA. Astenopia relacionada a distancia de visión y luminiscencia de monitores de pantallas LCD en trabajadores administrativos de Mota-Engil 2022. Rev Asoc Esp Espec Med Trab. 2024;33(2):172-82.

Seguí MM, Cabrero-García J, Crespo A, Verdú J, Ronda E. A reliable and valid questionnaire was developed to measure computer vision syndrome at the workplace. J Clin Epidemiol. 2015;68(6):662-73. doi:10.1016/j.jclinepi.2015.01.015

Singh S, Keller PR, Busija L, McMillan P, Makrai E, Lawrenson JG, et al. Blue-light filtering spectacle lenses for visual performance, sleep, and macular health in adults. Cochrane Database Syst Rev. 2023;8(8):CD013244. doi:10.1002/14651858.CD013244.pub2

Alenazi AH, Alshehri NM, Alshehri MA, Alhazmi TM. The prevalence and severity of computer vision syndrome among primary care health workers in the Ministry of National Guard Health Affairs, Central Region, Saudi Arabia. Cureus. 2024;16(11):e74741. doi:10.7759/cureus.74741

Published

2026-10-01

How to Cite

1.
Sánchez-Sanaguano FG, Flores-Pilco DA, Comas-Rodríguez R. Lighting levels and visual symptoms among employees of a food company in Machachi, Ecuador. SRS [Internet]. 2026 Oct. 1 [cited 2026 Nov. 28];4(especial7):299-305. Available from: https://www.revistasinstitutoperspectivasglobales.org/index.php/sanitas/article/view/1367