Telescopic crowns in removable prosthodontics: fabrication, materials and clinical outcomes

Authors

DOI:

https://doi.org/10.62574/55p0bh22

Keywords:

denture, partial, removable, dental prosthesis, dental technicians

Abstract

Objective: to analyze the evidence on laboratory fabrication, materials and clinical outcomes of telescopic crowns in removable prosthodontics. Methods: literature review with narrative synthesis in PubMed, SciELO and DOAJ; 15 documents were selected. Results: the primary crown is cemented onto the abutment and the secondary crown is part of the removable framework. Survival of telescopic abutments ranged from 82.5% to 96.5% at 3.4 to 6 years, and survival of tooth-supported dentures from 66.7% to 98.6% at 6 to 10 years. Electroformed secondary crowns and PEEK or PEKK secondary crowns maintained retention better than cast cobalt-chromium ones. Conclusion: telescopic crowns are a predictable option; their success depends on laboratory precision, the material combination and periodic follow-up.

Downloads

Download data is not yet available.

References

Verma R, Joda T, Brägger U, Wittneben JG. A systematic review of the clinical performance of tooth-retained and implant-retained double crown prostheses with a follow-up of ≥ 3 years. J Prosthodont. 2013;22(1):2-12. doi:10.1111/j.1532-849X.2012.00905.x

Seo JG, Cho JH. Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: an analytical review. J Adv Prosthodont. 2020;12(1):38-48. doi:10.4047/jap.2020.12.1.38

Verma M, Mutneja P, Gupta R, Gill S. Telescopic overdenture for oral rehabilitation of partially edentulous patient. Indian J Dent Res. 2019;30(3):468-71. doi:10.4103/ijdr.IJDR_69_17

Bayer S, Kraus D, Keilig L, Gölz L, Stark H, Enkling N. Wear of double crown systems: electroplated vs. casted female part. J Appl Oral Sci. 2012;20(3):384-91. doi:10.1590/S1678-77572012000300015

Linek W, Richter G, Raedel M, Walter M, Reitemeier B. In vitro analysis of the tribological behaviour of different material combinations for telescopic crowns. Metals. 2016;6(7):149. doi:10.3390/met6070149

Milić-Lemić A, Sredojević S, Radović K, Stamenković D, Miličić B, Popovac A, et al. Retention force of overdenture retained with telescopic crowns: a comparison of polyether ether ketone and zirconia ceramic telescopic crowns. Srp Arh Celok Lek. 2020;148(7-8):410-6. doi:10.2298/SARH190923025M

Micovic Soldatovic D, Bitter M, Meinen J, Huth KC, Liebermann A, Stawarczyk B. Impact of material combinations and removal and insertion cycles on the retention force of telescopic systems. Clin Oral Investig. 2023;27(7):4007-16. doi:10.1007/s00784-023-05027-w

Abdel Hamid SM, Selima RA, Basiony MZ. Surface topography changes and wear resistance of different non-metallic telescopic crown attachment materials in implant retained overdenture (prospective comparative in vitro study). BMC Oral Health. 2024;24:1123. doi:10.1186/s12903-024-04839-w

Ramadan RAM, Fadl SM, Ali SMAES, Ghali RM. Retention and wear assessment of novel PolyEtherKetoneKetone versus traditional cobalt chromium material used in digital double crown retained removable partial dentures. BMC Oral Health. 2026;26:1383. doi:10.1186/s12903-026-09411-2

Tribst JPM, Dal Piva AMO, Syed AUY, Alrabiah M, Al-Aali KA, Vohra F, et al. Comparative stress analysis of polyetherketoneketone (PEKK) telescopic crowns supported by different primary crown materials. Appl Sci. 2022;12(7):3446. doi:10.3390/app12073446

Bojović M, Todić J, Blagojević M. Comparative analysis of stress and deformation distribution in implant supported telescopic systems made of different materials. Vojnosanit Pregl. 2023;80(4):317-23. doi:10.2298/VSP210403049B

Awad SZS, Mourad KE, Sameh A, Albaqawi AH, Mostafa AZH. Three-dimensional finite element analysis of tooth and implant-supported telescopic prosthesis using zirconia, PEKK, and cobalt chromium crowns. BMC Oral Health. 2026;26:253. doi:10.1186/s12903-025-07607-6

Klotz AL, Hagspiel S, Büsch C, Zenthöfer S, Rammelsberg P, Zenthöfer A. Mid-term survival and complications of double-crown-retained removable dental prostheses placed in the dental practice: a retrospective study. Clin Oral Investig. 2025;29(1):26. doi:10.1007/s00784-024-06090-7

Wierichs RJ, Kramer EJ, Meyer-Lueckel H, Abou-Ayash S. Success and complication rates of non-precious alloy telescopic crowns in a general dental practice. Clin Oral Investig. 2023;27(12):7605-24. doi:10.1007/s00784-023-05350-2

El Asfahani IA, Khalifa A, Tawfik D, Agamy E, Salloum MG. A randomized controlled pilot trial comparing peri-implant tissue health beneath CAD/CAM-milled PEEK versus cobalt-chromium telescopic crowns for mandibular overdentures. Int J Implant Dent. 2026;12:21. doi:10.1186/s40729-026-00690-6

Published

2026-11-01

How to Cite

1.
Villalva-León CL, Sierra-Adasme BA, Carrasco-Carranza DA. Telescopic crowns in removable prosthodontics: fabrication, materials and clinical outcomes. CEOD [Internet]. 2026 Nov. 1 [cited 2026 Nov. 28];4(especial6):147-54. Available from: https://www.revistasinstitutoperspectivasglobales.org/index.php/COD/article/view/1553